description: "## Calamp Installation Manual [UL202_Wiring_Diagram.pdf](https://www.gsattrack.com/wiki/files/UL202_Wiring_Diagram.pdf) ## Protocol Details Default report rate is 9600/8/N/1 ``` Example report: *XD,205B,00,0000,0032,0000,0000,0260# ``` Calamp 2xx0 configuration details Changed S register 134 to 35 (termination character to 35(#) instead of 13 (\\\\n)) Changed S register 141…"
url: "https://help.globalsatellite.us/docs/ul-200-ultrasonic-fuel-sensor/"
updated: "2026-07-27"
category: Extras
---

# UL-200 Ultrasonic Fuel Sensor

## Calamp Installation Manual

[UL202_Wiring_Diagram.pdf](https://www.gsattrack.com/wiki/files/UL202_Wiring_Diagram.pdf)

## Protocol Details

Default report rate is 9600/8/N/1

```
Example report: *XD,205B,00,0000,0032,0000,0000,0260#
```

Calamp 2xx0 configuration details

Changed S register 134 to 35 (termination character to 35(#) instead of 13 (\\n))

Changed S register 141 changed from 0 to 6 to report every 6th message. This will be once per minute as the fuel level is reported every 10 seconds

Changed S register 135 changed from 200 to 36 to send single reports

Changed S register 136 changed from 0 to 1 to ID reports as UL200 reports

### Required parts

RS232 Male cable

Calamp Serial Adapter 133337/D3

1x Header [1445022-5](http://www.mouser.com/ProductDetail/TE-Connectivity-AMP/1445022-5/?qs=UpGkl3le9EMsAs5NsZdvPg==)